Making a test suite safe to run in parallel worker processes

What a .NET integration suite has to satisfy before Bobcat's supervisor can split it across worker processes, and the failure modes to expect on the way. Written from four real suites — Wolverine's PersistenceTests and Redis.Tests, Polecat's Polecat.Tests, and Bobcat's own — so the list is what actually broke, not what might.

Measured so far

SuiteTestsSequential4 workersResult
Polecat.Tests1587954s366s (2.6x)1587/1587 after two fixes
Wolverine PersistenceTests78164s73s (2.2x)78/78, no source changes
Wolverine Redis.Tests144452s206s (2.2x)144/144, no source changes

All three plateau quickly — 8 workers bought 4% over 4 on Polecat and 3% on Redis — but for two different reasons, and the difference decides whether the plateau is worth attacking.

On Polecat it is contention: beyond a handful of lanes the database container is the bottleneck rather than the worker count. More hardware would move it.

On Redis it is arithmetic. Partitioning is by class, so a class cannot be split, so the largest class is a floor no fleet size goes below:

ceiling = sum(all test durations) / largest class's total duration

Redis is 599s of test time with a 188s compliance class in it, so the ceiling is 3.19x and the floor is ~188s. Measured: 199s at 8 workers. The prediction cost one run; the curve that confirmed it cost four. Worth computing before provisioning a fleet — if the ceiling is 3x, asking for 8 workers buys nothing but containers.

When the floor is what binds, the fix is not more workers. It is splitting that class, or making the tests in it faster: two compliance classes were 61% of the Redis suite's total test time.

Step 0 — be an MTP host

The supervisor drives the test executable over Microsoft.Testing.Platform's server mode. It never loads the test assembly, so a test project needs no reference to Bobcat. It does need to be an MTP host rather than an xUnit native runner:

xml
<OutputType>Exe</OutputType>
<UseMicrosoftTestingPlatformRunner>true</UseMicrosoftTestingPlatformRunner>

Check with ./YourTests --list-tests. If that errors with unknown option, you have the xUnit native runner and the supervisor cannot drive it.

UseMicrosoftTestingPlatformRunner changes only the executable's entry point — the VSTest adapter path is untouched, so dotnet test, --filter, TRX and coverlet keep working. Verified on Wolverine, which runs xUnit v3 in VSTest compatibility mode: dotnet test --filter "Category!=Flaky" still reported 160 passed with the property set.

Hazard: same output path, different entry point. A build without the property silently yields a non-supervisable executable. Put it in Directory.Build.props, not a per-job -p: override.

Hazard (found on CritterWatch): a test project with <GenerateTargetFrameworkAttribute>false</GenerateTargetFrameworkAttribute> breaks the xUnit v3 VSTest adapter — the assembly reports UnknownTargetFramework, the adapter's process launcher cannot decide how to start the (now-executable) project, and every dotnet test run dies with Catastrophic failure: … Could not launch test process. The exe itself still answers --list-tests and -automated, which makes the symptom look like an adapter bug rather than a project-property one. Strip the property from test projects when migrating to v3; suites carry it for assembly-version-reporting reasons that never apply to a test host.

Hazard (found on CritterWatch): pathological test output breaks the MTP wire. MTP server mode is JSON-RPC, and Microsoft.Testing.Platform's serializer throws ArgumentException: The JSON value of length N is too large on any single string past ~½GB — at which point the worker faults and every unreported test goes Indeterminate. A CritterWatch test was dumping a 698MB tracked-session log into ITestOutputHelper; dotnet test had been silently absorbing it into an 868MB TRX nobody read, so the supervisor was the first consumer to notice. The fix is fixing the test (the giant output traced to a real message loop), not widening the wire — but recognize the signature: worker fault carrying Json.SerializeAsync + ValueTooLarge, with a pass/indeterminate split at the choke point. Sister symptom for triage: on Bobcat before 0.7.0 those indeterminates printed as uid hashes, not display names — fixed by issue #82, which carries the discovery display name onto synthesized never-reported outcomes.

Step 1 — the partitioning contract

The supervisor splits work by test class, never by individual test. That is a correctness rule, not a tuning choice: every framework's isolation contract is per class or collection, so a class's fixtures and static state assume one process.

Splitting Wolverine's suite per test failed 1–4 tests non-deterministically; per class it was 78/78 at the same wall clock. The mechanism was a class whose setup read

csharp
var schemaName = "sqlserver" + ++count;   // static int

Split across four processes, each restarts at zero and all four collide. Nothing about that is visible in the test list, which is why the rule has to be conservative.

You inherit this for free. The thing you must supply is what follows.

Step 2 — per-worker resource isolation

Class-level partitioning keeps a class together. It cannot stop two different classes that share a database landing in different workers. So each worker needs its own database:

csharp
new MtpWorkerFactory(path)
{
    EnvironmentFor = worker => new Dictionary<string, string>
    {
        ["POLECAT_TESTING_DATABASE"] = connectionStringFor($"polecat_w{worker.Lane}")
    }
}

Lane is bounded by MaxParallelWorkers, so you provision as many databases as workers you asked for. That requires the suite to take its connection string from an environment variable — most already do; Wolverine's Servers.cs was hardcoded constants and needed a small change.

A suite that starts its own container per process already has this, for free. Wolverine's Redis tests spin up a Testcontainers Redis from a [ModuleInitializer], so every worker gets its own broker with its own port and there is nothing to wire — which is why that suite parallelised with no source changes at all. Check for this before building per-worker plumbing.

Two things it costs, both worth knowing rather than discovering:

  • Every process pays the container start, before Main, on the critical path — ~0.85s for redis:7-alpine including discovery, and far more for heavier images. Irrelevant at four workers; it dominates any mode that starts one process per test.
  • Nothing reaps those containers if the reaper is off. A [ModuleInitializer] that never disposes leaks one container per process; with Testcontainers' Ryuk disabled this reached 49 orphans on one machine. Not Bobcat's bug, but Bobcat's process multiplication is what makes it visible.

Step 3 — the three bugs this exposes

All were found in real suites, all silent, and all are the reason a first parallel run goes red.

Text-rewriting a connection string

csharp
// WRONG — only rewrites while the catalog happens to be "master"
ConnectionSource.ConnectionString.Replace("Initial Catalog=master", $"Database={name}")

Point the environment variable at anything else and the literal is absent, the replace matches nothing, and the "other" database quietly resolves to the current one. The test then asserts against itself and passes or fails for reasons unrelated to what it tests. Use a DbConnectionStringBuilder.

The same shape appears as assertions that bake the environment into an expected value:

csharp
var expected = new Uri("wolverinedb://postgresql/localhost/postgres/wolverine");

That one is honest about what it is — it just cannot survive a renamed database.

Server-scoped names

A database a test creates is a sibling of the worker's database, not a child of it. Per-worker catalogs therefore do not isolate them, and a hardcoded name is one object shared by every worker:

csharp
// WRONG — every worker races to create and drop the same database
private const string DbA = "polecat_tenant_a";

// RIGHT — carries the worker's scope
private static readonly string DbA = ConnectionSource.Scoped("tenant_a");

Under four workers this surfaced as "User does not have permission to alter database 'polecat_tenant_a'" — non-deterministically, which is the signature of contention rather than a deterministic bug.

Applies to anything at server scope: databases, logins, linked servers, Agent jobs, and any fixed TCP port a test binds.

Schema names do not need this. They live inside the catalog, so per-worker databases already separate them. Polecat has SchemaName = "doc_usage" in nine files and it is fine.

Environment-dependent test identities

A theory whose data is computed from the environment gives the same test a different identity in every worker:

csharp
// WRONG — the argument (and therefore the test's uid) depends on which worker computes it
public static IEnumerable<object[]> AgentUris =>
    [[$"wolverinedb://postgresql/localhost/{Servers.PostgresDatabaseName}/wolverine"], ...];

// RIGHT — a stable sentinel, resolved inside the test body
[InlineData("default")]
public async Task build_each_agent_smoke_test(string uriString)
{
    var uri = uriString == "default"
        ? new Uri($"wolverinedb://.../{Servers.PostgresDatabaseName}/wolverine") : uriString.ToUri();

The supervisor discovers in one process and executes in another with a different per-worker environment, so the uid the plan asks for does not exist in the worker that receives it. Found on Wolverine's MartenTests: the symptom is "the worker finished without reporting a result for this test" — reported as indeterminate, and a retry appears to "fix" it whenever the retry process happens to compute the same environment discovery did, which makes it masquerade as an ordinary flake. Test identity must be a function of the code alone, never of the environment.

Step 4 — containers

DockerComposeResource starts the containers and knows when they are usable. Readiness comes from the compose file's own healthcheck, not from a Bobcat package per image — the healthcheck lives where the credentials and ports already are.

Four descending tiers, and the one used is reported in ReadinessSource so a weak check is never silent: a supplied Probe, then the declared healthcheck, then a TCP connect, then "the container is running" (which only means the entrypoint has not exited).

Recycle() uses --force-recreate rather than restart, because recycling means throwing the thing away.

When a parallel run hangs, bloats, or is cut short

Everything here is off by default and reporting-first — the same guardrail as the timing report.

  • HeartbeatInterval emits one log line however many lanes are running, leading with the longest-running test — a stuck run shows as that figure climbing before any threshold fires.
  • StallThreshold (and per-test StallThresholdFor) fires a TestStalled observer callback and a STALLED: log line once per attempt, collected on SupervisorResults.StalledTests. Whether the supervisor then acts is the separate, opt-in StallAction: Report (default), KillAndRetry (kill the wedged worker, give the stalled test one fresh-process retry, resume its innocent batch-mates in their lane), or AbortRun. Stall-managed outcomes never spend the RetryBudget and never count as flaky — a wedge is not a flake.
  • MtpWorkerFactory.OnBeforeKill hands you the live process (with its pid — the supervisor surfaces it, never guesses) before a forced kill, which is where a dotnet-dump collect belongs.
  • ResourceSampleInterval brackets every attempt with worker RSS samples; per-test retained deltas are attributed only when the attempt had the process to itself, and unmeasured is never zero-filled.
  • Supervisor.Snapshot() is what a cancelled run leaves behind: wire your CI job's SIGTERM to it and write the flakiness ledger from a result stamped IsPartial, instead of losing the whole run to a capped job.

Triage order for a red first run

  1. Deterministic and database-name-shaped — text-rewritten connection strings, or assertions naming the database. Fix the suite; these are latent bugs regardless of parallelism.
  2. Non-deterministic, moves between runs — server-scoped name collisions. Scope the names.
  3. Non-deterministic, same class every time — a class split across workers. Report it: the partitioner should have prevented this.

A fourth shape is worth ruling out before the first parallel run rather than triaging after it: a test that only ever passed because something else ran first. That sweep is built — IsolationSweep (in Bobcat.Supervisor) runs every partition alone, diffs against a baseline full-suite run, and classifies what moved: OrderDependent (passed with the suite, failed alone — the bug this exists to find), InterferenceVictim (the same defect seen from the other end), FailedInBoth (ordinary red), and EnvironmentSensitive (failed in the concurrent sweep but passed a serial confirmation run — the sweep's own contention, deliberately reported rather than counted). Granularity defaults to per-class, matching what the supervisor actually guarantees; per-test is strictly finer and catches ordering within a class at the cost of one process per test. It is the one class of failure that parallelism exposes without having caused.

What this does not buy you

Parallelism speeds up a suite; it does not make a flaky one reliable. If stability is the problem, that is the retry/quarantine half of the supervisor (RetryBudget, @retry, @isolated, RecoveryHint), and it is a separate decision — Polecat needed none of it.

Nor does it fix a suite dominated by one slow test. Wall clock is the slowest lane, so the largest partition sets the floor: Wolverine's run bottomed out at ~67s because one test slept for 61 of them. The evidence for attacking that is in the run itself: RunReport's Timing section ranks the slowest tests by share of wall clock, reports parallel efficiency, and prices retries and isolation — report, don't act, so whether a slow test is a bug or honestly slow stays a judgement. Across runs, the committed ledger (TestLedger, see ledger-design.md) carries duration trends, and ledger.KnownDurations() feeds the lane balancer so a second run balances on measured durations instead of test counts.

And it does not shorten a CI run whose wall clock is set by a different job. Wolverine's matrix runs ~30 jobs concurrently, so the workflow takes as long as its slowest; parallelising the Redis job from 9m to 5m moved that number by zero, because two 18m jobs set it. Measure which suite is on the critical path before optimising the one in front of you.